Skip to content

Product Test Data

Pool House Glass Walls in SD

A Commitment to Continuous Improvement

During the testing phase, our team conducted several iterations of enhancements to optimize the door’s performance. These refinements included adjustments to gasket placement, and threshold sealing, all meticulously documented and verified through independent testing. With each iteration, the system demonstrated improved results, culminating in a final configuration that surpasses industry standards.

Engineering Excellence Through Progressive Design & Rigorous Testing

At HydAway Hydraulic Walls, we are committed to delivering industry-leading performance through continuous innovation and rigorous testing. Our latest hydraulic-powered operable door system has undergone multiple rounds of design refinement and performance validation to ensure unmatched structural integrity and air-tightness.

Final Performance Results: Unmatched Air-Tightness & Structural Strength

Airtight

The final test results achieved an exceptional 0.10 cfm/sq ft air infiltration rating at 1.57 psf, classifying this door as “extraordinarily airtight.”

Watertight

The door gasket system allowed no uncontrolled water penetration during a 15 minute water test with an 8.0 psf pressure differential and water spray from the outside at 5 gal/hr/ft2.

Hurricane Ready

Structural testing confirmed that the door withstands up to 75 psf positive and negative pressure, which equates to winds of 255 mph—exceeding hurricane-force wind speeds.

Rock Solid

Even under the extreme structural wind loads, deflections were measured in the thousandths of an inch, ensuring long-term durability and stability.

HydAway Walls & Doors Pool House

Test Procedure Summary

  • Open, Close, Lock Door Cycling: 5 Complete open/close cycles
  • ASTM E330/E330M-14(2021): Preload @ 25.0 psf inward pressure
  • ASTM 3283/E283M-19: Static Air (1.57 psf)
    • Passed: 0.1 cfm/sq ft
  • ASTM E331-00(2023): Static Water (8.0 psf)
    • Passed: No uncontrolled water penetration
  • ASTM E330/E330M-14(2021): Structural Loads @ 50.0 psf
    • Passed: No deflection normal to wall plane for framing members exceeding L/175
  • ASTM 3283/E283M-19: Repeat Static Air (1.57)
    • Passed at 0.1 cfm/sq ft
  • ASTM E330/E330M-14(2021): Structural Overloads @ 75.0 psf
    • Passed: No permanent set of main framing members exceeding 0.2% of clear span

HydAway Hydraulic Walls Performance

Our commitment to performance-driven innovation ensures that HydAway Hydraulic Walls meet and exceed the most demanding environmental and structural requirements. Through continuous refinement and meticulous testing, we deliver a product engineered for reliability, efficiency, and superior protection against the elements.

For more details on our testing process and results, or to request a copy of the full test report, contact us today! To view a summary of the final test results, simply click the button or see the content below.

HydAway Walls & Doors Bar

With fabrication and service centers across North America, our products, service and support are always close by. Choose a location that suits you.